AXIS#.SM.I2

Description

AXIS#.SM.I2 defines the current that is used in service motion mode 1 and 2 (see AXIS#.SM.MODE).

Versions

Action Version Notes
Implemented 02-00-00-000

General Information

Type

Read/Write

Units

Arms

Range

± Drive peak current (AXIS#.IPEAK )

Default Value

-0.266 Arms

Data Type

Float

See Also

Service Motion, AXIS#.SM.I1

Stored in Non-Volatile Memory

Yes

Variants Supported

All variants are supported.

Fieldbus Information

EtherCAT CoE and CANopen

Command

Index

SubIndex

Data Type

Units

Float Scale

Access

PDO Mappable

AXIS1.SM.I1

500eh

01h

Signed32

-

1000:1

Read/Write

No

AXIS1.SM.I2

500eh

02h

Signed32

-

1000:1

Read/Write

No

AXIS2.SM.I1

510eh

01h

Signed32

-

1000:1

Read/Write

No

AXIS2.SM.I2

510eh

02h

Signed32

-

1000:1

Read/Write

No

EtherNet/IP

ID

Instance

Attribute

Name

Data Type

Access

User Mappable

6400

1

6400 (0x1900)

AXIS1.SM.I1

Signed32

Read/Write

Yes

71936

2

6400 (0x1900)

AXIS2.SM.I1

Signed32

Read/Write

Yes

6401

1

6401 (0x1901)

AXIS1.SM.I2

Signed32

Read/Write

Yes

71937

2

6401 (0x1901)

AXIS2.SM.I2

Signed32

Read/Write

Yes

PROFINET

Parameter

PNU

Data Type

Access

Units

AXIS#.SM.I1

6400

Float

Read/Write

-

AXIS#.SM.I2

6401

Float

Read/Write

-